BVWBF - FERRO FREE 20 ELECTROSTATIC SOLUTION, 83-7-106566

  • MSDS: BVWBF
  • Manufacturer: AM MULTIGRAPHICS
  • Product Name: FERRO FREE 20 ELECTROSTATIC SOLUTION, 83-7-106566
  • National Stock Number: 6850-00N053957
Product Identification

Product ID:FERRO FREE 20 ELECTROSTATIC SOLUTION, 83-7-106566
MSDS Date:03/01/1994
FSC:6850
NIIN:00N053957
MSDS Number: BVWBF

Responsible Party
AM MULTIGRAPHICS
1800 WEST CENTRAL ROAD
MT PROSPECT, IL 60056
US

Emergency Phone: 708-870-5121;708-398-1900

Info Phone: 708-870-5121;708-398-1900

Cage: 0FTL5

Contractor
AM MULTIGRAPHICS DIV OF AM INTL INC
MOUNT PROSPECT, IL 60056-6048 US

Telephone: 847-375-1700

Cage: 09177

Ingredients

INOSITOL, HEXAKIS (DIHYDROGEN PHOSPHATE), MYO-; (PHYTIC

CAS: 83-86-3

RTECS: NM7525000

Fraction By Weight: 8-11%

OSHA PEL N/K

ACGIH TLV: N/K


ADIPIC ACID (SARA III)

CAS: 124-04-9

RTECS: AU8400000

Fraction By Weight: 4-6%

OSHA PEL N/K

ACGIH TLV: 5 MG/M3

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


MALONIC ACID; (CARBOXYACETIC ACID)

CAS: 141-82-2

RTECS: OO0175000

Fraction By Weight: 3-5%

OSHA PEL N/K

ACGIH TLV: N/K


ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL)

CAS: 111-76-2

RTECS: KJ8575000

Fraction By Weight: 0.5-1%

OSHA PEL 50 PPM,S

ACGIH TLV: 25 PPM,S


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 79-82%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:MILD IRRITATION. SKIN:MILD
IRRITATION. INHAL:MAY CAUSE MILD DROWSINESS. INGEST:MAY CAUSE
GASTRIC DISCOMFORT. ANIMAL STUDIES CLEARLY DEMONSTRATED
DOSE-RELATED ADVERSE EFFECTS ON THE CNS, THE HEMATO POIETIC TISSUE,
THE BLOOD, THE KIDNEYS,AND THE LIVER ASSOCIATED WITH THE
ADMINISTRATION OF ETHYLENE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:GLYCOL MONOBUTYL ETHER (EGBE)
(EXTRACTED FROM DHHS (NIOSH)) PUBLICATION NO. 90-118) .
Medical Cond Aggravated by Exposure:NONE

First Aid

First Aid:EYES:IMMEDIATELY FLUSH EYES THOROUGHLY WITH LARGE AMOUNTS OF
WATER FOR AT LEAST 15 MINUTES, AND SEEK MEDICAL ATTENTION IF
IRRITATION PERSISTS. SKIN:WASH THOROUGHLY WITH SOAP AND WATER,
REMOVE CONTAMIN ATION CLOTHING. INHAL:REMOVE VICTIM TO FRESH AIR.
SEEK MEDICAL ATTENTION IF NECESSARY. INGEST:DRINK ONE OR TWO
GLASSES OF SALT WATER AND INDUCE VOMITING BY STICK FINGER DOWN
THROAT. CALL PHYSICIAN.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE EXTINGUISHING MEDIA FOR SURROUNDING FIRE .
Fire Fighting Procedures:NIOSH/MSHA APPROVED SCBA AND FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:FLUSH MATERIAL DOWN TO SEWER WITH LARGE
AMOUNTS OF WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT TAKE INTERNALLY. VENT IN WORK
AREA SHOULD BE SUFFICIENT. REMOVE & WASH CONTAM CLOTHES QUICKLY.
STORE PROD IN WELL-VENT AREA, AWAY (SUPP DATA)
Other Precautions:FOR COMMERCIAL/INDUSTRIAL USE ONLY. DO NOT REUSE
CONTAINER. KEEP FROM REACH OF CHILDREN.

Exposure Controls

Respiratory Protection:NOT NORMALLY REQUIRED. NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:NOT NECESSARY.
Protective Gloves:LATEX OR NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGG .
Other Protective Equipment:RUBBER OR PLASTIC APRON.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
HNDLG/STOR PREC:FROM EXTREME HEAT AND FIRE HAZARDS.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:212F,100C
Vapor Pres:.023 @ 20
Vapor Density:1.0
Spec Gravity:1.08 (H*2O=1)
pH:4.36
Solubility in Water:COMPLETE
Appearance and Odor:CLEAR PINK LIQUID. NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE

Disposal

Waste Disposal Methods:CONSULT WITH FEDERAL, STATE, AND/OR LOCAL
REGULATORY AGENCIES FOR APPROPRIATE DISPOSAL METHODS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.